Soft pack power battery DCIR test equipment
  • Product Details
Capacity 12PPM
Operating Voltage AC380V±10%, 50Hz
working pressure 0.4-0.6MPa
Voltage

Discharge voltage setting range: 2500-5000mV

Voltage setting resolution: 1mV

Voltage setting accuracy: ±2mV

Voltage measurement resolution: 0.1mV

Voltage measurement accuracy: ±2mV

Measurement cycle: 100mS

Time resolution: 100mS

Current

Discharge current setting range: 200-200000mA

Current setting resolution: 1mA

Current setting accuracy: ≤±200mA @0.1% FS

Current measurement resolution: 1mA

Current measurement accuracy: ≤±200mA @0.1% FS

Measurement cycle: 100mS

Time resolution: 100mS

Equipment size 2430 x 1960 x2700mm
equipment weight 1700kg